1, Features:
Application capacity
Max.number of collectors:1
Max.number of storage tanks:1
Max.number of relays:3
Max.number of sensors:5
Max.number of application system:1
2, Technical datas:
<1> Dimension: 420x280x155mm
<2> Power supply: 200V-240V AC or 100V-130V AC,50-60Hz. .
<3> Power consumption: < 3W
<4> Accuracy of temperature measuring: ± 2oC
<5> Range of collector temperature measuring: -10oC ~200oC
<6> Range of tank temperature measuring: 0oC ~100oC
<7> Suitable power of pump: 2 pumps possible to be connected, power of each pump < 200W .
<8> Suitable power electrical heating:1 relay for 1500W(1500w-4000w must be use SR802)
<9> Inputs: 5sensors,
1pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
4pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
<10> Outputs:3 relays, for circulation pumps or 3-way electromagnetic valve
<11> Ambient temperature:-10oC ~ 50oC.
<12> Water proof grade: IP42.
3, Main functions:
<1> Pump support: Normal/high efficiency pump
<2> Set up clock/week
Functions operation and parameters setup (user grade)
<3> THET Timing heating
<4> CIRC DHW water circuilation function
<5> TCYC Tempeature or time setting for DHW pump in three time sections
Functions operation and parameter setup (engineer grade)
<6> DT Temperature difference for solar circuit pump
<7> EMOF Maximum switch-off temperature of collector (for collector emergency close function)
<8> CMX Maximum limited temperature of collector (collector cooling function)
<9> CMN Low temperature protection of collector
<10> CFR frost protection temperature of collector
<11> SMX Maximum temperature of tank
<12> REC Recooling temperature of tank
<13> C_F Switch between Celsius and Fahrenheit
FUN Auxiliary functions
<14> DVWG Anti legionnaires' function
<15> P1 Pump P1 operation mode selection
<16> nMIN Pump speed adjustment(RPM control)
<17> DTS Standard temperature difference of pump (for speed adjustment)
<18> RIS Gain for circulation pump (speed adjusting)
<19> Pump P2 operation mode selection
<20> FTYP Flow meter type selection
<21> OHQM Thermal energy measuring
<22> FMAX Flow rate
<23> MEDT Type of heat transfer liquid
<24> MED% Concentration of heat transfer liquid
<35> INTV pump Intermission function
<26> tSTP Pump interval run-off time
<27> tRUN Pump interval run-on time
<28> AHO /AHF Automatical thermostat function
<29> COOL Tank cooling function
<30> BYPR Bypass function (high temperature)
<31> HND Manual control
<32> PASS Password set
<33> LOAD Recovery to factory set
<34>“ON/OFF” Controller switch on/off button
<35> Holiday function
<36> Manual heating
<37> Manually control DHW pump
<38> Temperature checking function
<39> Protection function
<40> Memory protection
<41> Screen protection
<42> Pump dry running protection
<43> Trouble shooting
<44> Trouble protection
<45> Trouble checking
4, Payment
<1> T/T(wire transfer)
<2> L/C at sight
<3> 30% T/T in advance as deposit, the rest paid before shipment
<4> 30% T/T in advance as deposit, the rest paid against B/L copy
5, Our advantages:
<1> We have 8 senior engineers working on development. that will make us lead the trend whatever on structure or technolgy
<2> 15 QC control the quality, just make sure all is right
<3> Aftersale service is quick, any problem you mentioned will be dealt with in 24 hours!
<4> Our professional salesmen always online for your questions
6, Contact:
Mr Krista Zhang
Position: Sales manager
Phone: 86-573-87090146
Mob/Whatsapp: +8618857389277
Facebook/Wechat: Zilansolar
Twitter: zhangkrista Skype: Krista025
Website: www.zilansolar.com
For more details, pls send email to us, thanks!